Thursday, June 1, 2017

1920: The Lungmotor (a resuscitation device)

Lungmotor carrying case.
The Lungmotor was a simple device for assisting emergency crews during the 1910s and 1920s. It's intended use was for patients exposed to gases, electrocutions, or near drownings. 

As you can see by the pictures, it was basically a pump, like a bicycle pump, connected to the patient by tubing and a mask that fit over the patient's mouth and nose.

The Lungmotor with case and booklet.e
The company booklet, simply titled "The Lungmotor," basically recommended the device for near drownings.  The recommendation was for immediate removal of patient from the water. Manual methods should be used to remove mucus and water from the mouth and to provide breaths until the Lungmotor was on the scene.

 "The LUNGMOTER," the booklet says, "will remove the remaining water and mucus at the same time supplying a sufficient volume of air to resuscitate the victim." (1, page 8)

It's "a simple and easily understood device."  (1, page 14)

The LUNGMOTOR consists of two air pumps which operate in unison, yet are not connected in any way as far as the interchange of air is concerned. At no time does the devitalized air come in contact with the fresh air or oxygen.

The Lungmotor was supposedly "foolproof." Operating it was generally "easy," according to the booklet. To operate it all you had to do was: (1, pages 9, 11, 15)
  1. Set the pin to the approximate size of the victim: (1, pages 9, 15)
    • Newborn
    • 5 Years
    • 10 Years
    • 15 Years (or small adult)
    • Adult Average
    • Adult Large
  2. Place the mask on the patient  (1, page 11)
  3. Pump (1, page 11)
The booklet, thus, notes various advantages of their product over competitor products: (1, page 13)
  1. Easy to carry
  2. Easy to understand
  3. Easy to use
  4. It's worked by hand
  5. It can always give air (the kind you use every day)
  6. Or you can add an oxygen tank to supply supplemental oxygen
  7. Easy to increase and decrease volume (just move the pin)
  8. It's safe and sure
A picture of the Lungmotor.
showing predicted tidal volumes
based on size of patient.
A pin was inserted
at the appropriate age
to prevent barotrauma.
 (1, page 9)
It also offers other physiological advantages to the patient: 

1.  It delivers the exact volume of air necessary to maintain the circulation and respiration over a long period of time. This is, as noted above, determined by setting the pin to the estimated size of the patient. (1, page 14)  Thus: 
The LUNGMOTOR does the very next thing to normal breathing because it supplies, mechanically, the tidal volume of air each respiration (the amount you breathe at rest), enough air, but not so much as to possibly injure the Lung tissues and the circulation, thus not leaving the patient liable to pneumonia following. (1, page 
2.  It always gives air to lungs, not stomach:  "This is accomplished by means of a tube which is introduced into the gullet and a bulb on the end blown up bv means of a hand bulb, and a soft rubber tube clamped by a clip. This tube is easily inserted because when pushed backward and down, guided by the under finger, it can go no place else but into the gullet." (1, page 14)

3.  It prevents you from providing too much pressure to patient "thus making it impossible to rupture the delicate tissue of the lungs."  This is due to the operator setting the pin to deliver the appropriate volume of air according to the size of the victim.  (1, page 14)

4.  It offers suction.  This causes expiration, and also allows for the device to "remove instantly and positively the large quantities of slime, mucus and blood that accumulate in the air passages, thus making it possible for the air to be delivered to the lungs which is not always possible (with manual resuscitation)." (1, page 14)

The fact that it offers suction is noted as one of the major advantages of the product, as noted by this passage: (1, page 13)
The fact that it reestablishes the suction action of the thorax on the heart and great vessels in addition to supplying the lungs with the correct amount of fresh air, is the explanation of the wonderful results obtained by the use of the LUNGMOTOR. The unsatisfactory results of past experiments in mechanical resuscitation were due to a failure to attach to this phase of the subject the importance which it deserved. (1, page 13, 18)
5.  It can provide oyxgen:  When not connected to an oxygen tank it supplied room air to the patient, which contains about 21% oxygen.  An oxygen cylinder could also be attached to the device in order to supply the patient with supplemental oxygen. (1, page 9)

6.  No risk of damaging a rib or liver, as often occurs with manual methods of resuscitation.  This risk is "entirely eliminated" with the Lungmotor, at least according to the booklet.

By this photo you can see the simplicity of the device.
It basically consisted of the cylinders, the handle,
and the mask.  (1, page 16)
So, how does it all work?  Again, according to the booklet:
The LUNGMOTOR consists of two cylinders which operate in unison, yet not connected in any way as far as the interchange of air is concerned. At no time does the divitalized air come in contact with the pure air and oxygen.
An upward movement of the handle charges the inspiration cylinder with pure air or any mixture of air and oxygen desired, according to the setting of the mixing valve (b). At the same time the expiration cylinder is filled with the expired air gently expelled from the lungs by the patient due to the natural contractual power of the chest walls and the elasticity of the lungs.
Conversely the following downward movement of the pump handle and piston places the air or the mixture of air and oxygen into the lungs and discharges the impure air through the outlet (o) into the atmosphere. In the case of drowning or new-born babies the water, blood, mucus, etc., is taken care of through the device and discharged at this opening (o).
Thus you see that at every complete stroke of the handle up and down you have a complete respiration, an inspiration, and an expiration—normal breathing mechanically done. (1, pages 14-15)
An early concern of manufacturers of mechanical resuscitators
was to make sure that expired air was kept separate from inspired air.
This was necessary to prevent patients from re-breathing
exhaled air, or exhaled carbon dioxide (CO2).  For this reason
the Lungmotor was designed with 2 separate cylinders,
one for inspiration (left) and one for exhalation.   (1, page 15)
The average breath given to an adult is estimated to be about 700 cc of air, which is "sufficient to maintain life, being, in fact, about 150 cc more than the patient normally breathes; this 150 cc. of air being used to counterbalance the natural resiliency of the lung in order to maintain the normal pressures in the thoracic cavity, and aid mechanically the restoration of the automatic mechanism of circulation by removing the obstruction in the lung, caused by the arteries crooking upon themselves when unconsciousness occurs. " (1, page 6-7)

The makers of the Lungmotor recommended the product be available for use by Rescue Teams, and that when someone was noted to be in a state of "suspended animation" that the rescue team be called for right away. However, in the meantime: "We believe manual methods if there are no other means of resuscitation available. But the use and the results from manual methods are limited." (1, page 6, 17)

Manual breaths, therefore, should be given, preferably by using Prone Method (Shaeffer Method), until the Lungmotor arrives on the scene.  

Criticism of the device was generally similar to any other mechanical resuscitator of the day, that it forced too much air too fast into the lungs, sucked too much air out of the lungs, and could only be used for a short period of time due to worker fatigue.

Note:  An advertisement for the Lungmotor can be found in "Modern Hospital," January, 1915, volume 36, number 1,  page 39

References: 
  1. "Drowning: Historical-Statistical Methods of Resuscitation," no author nor editor listed, Published by Lungmotor Company, Boston, Massachusetts, 1920

Wednesday, April 27, 2016

1792: The first attempts at neonatal resuscitation

Fig. 1 -- Represents the box-wood tube.  One end was inserted
into the infants airway.  The caregiver would lace his mouth
over the other end (bottom of the figure in the photo) and provide
breaths to the child.  Bellows may also be connected to the tube.
(14, page 77-78, 196)
Perhaps among the first attempts at artificial respiration were performed on a stillborn child. The mother and father waited patiently for nine months, a perfectly formed child was born, but it wasn't breathing.  Frantic attempts were made to excite breathing.

More often than not such attempts failed, but every so often there was success, which brought great joy and excitement, just enough to motivate the next generation to make such efforts given the same frightful situation.

Some methods used to excite a newborn's first breath included: (1, page 77) (2, page 13)
  1. Talking to the baby
  2. Rubbing the baby's chest 
  3. Shaking the baby
  4. Tickling the baby
  5. Blowing in the baby's face
  6. Warming the baby with warm blankets
  7. Applying moderate friciton to the body by rubbing 
  8. Slapping the baby on the back or heels
  9. Patting the baby on the back
  10. Squeezing the rib cage
  11. Hugging the baby
  12. Performing mouth to mouth respirations, what was called inflating the lungs
  13. Inserting a tube into the airway and breathing for the child that way 
  14. Suctioning the baby's airway (not available until 1937)
  15. Performing gentle chest compressions or abdominal thrusts
  16. Tickling the nose with a feather
  17. Tickling the arm pits, temples, stomach
  18. Dunking the child up to the neck in warm water
  19. Other gentle stimilation
Over time, and by trial and error, better methods were developed. By the end of the 19th century a basic form of neonatal resuscitation was taught to medical students, nurses, midwives, and members of societies such as the Humane Society. In fact, the report references and quotes Curry. 

A good example can be found in James Curry's 1815 book "Observatoins on Apparent death:"
WHEN a still-born Child appears in every respect perfect, and especially when, from the circumstances of the labour, there is reason to believe that the Child has not been long dead, measures may be taken for recovery, with very great hopes of success. With this view, the Lungs should be diligently inflated, and the heat of the body kept up, by the application of Warm Flannels, or by putting the Feet and Legs, or the whole Body up to the chin, into Warm Water. Moderate frictions with the Naked Hand, and gentle agitations, may also be used; and Stimulating Remedies applied to the Nose, Temples, and Pit of the Stomach. (1, page 77-78)
If these efforts did not work, then the physician or midwife would move on to the next stage of the resuscitation attempt, which would involve inserting tubes into the airway and breathing for the baby.  An example of this is noted by Curry:
If the Wooden Tube (Fig. 1.) be not at hand, the female Catheter (an instrument which every Practitioner in Midwifery is presumed to carry constantly about with him) will answer tolerably well for inflating the Lungs in this case: in defect of it, a joint of reed, the barrel of a qiull, or a piece of still paper or a card rolled up, may be; —one end being introduced into the Mouth, and the Assistant blowing into the other with his breath,* until the Lungs are expanded; then gently pressing the Chest;—and repeating this, so as to imitate Natural Respiration.
The recommendation by the Humane Society was similar, although the 1823 report of the Society suggested that bellows should be used to breathe for stillborn infants instead of the mouth.

Curry notes that in "some cases which have come within my knowledge prove, that Still-born Children may be recovered even after an hour or more has elapsed." His explanation for this is as follows: 
There are several reasons for believing, that the Vital Principle is not so soon destroyed here, provided the warmth of the body be kept up, as when Respiration has been established for a length of time, and then interrupted: for the new-born Infant which has either not respired at all, or had its breathing suspended very soon after birth, seems in a state of susceptibility somewhat resembling that which annually takes place in certain Animals, as the bat, frog, dormouse, &c, from the influence of the Winter's cold; the one requiring only the restoration of that warmth by the return of Spring, the other the application of Air to the Blood stagnating in its Lungs, to restore the Circulation, and with it the balance of functions necessary to Life. 
His theory is actually quite interesting considering anatomical pathology was only in its infancy during this era.  Over the ensuing years better wisdom improved the steps of neonatal resuscitation.  However, it wouldn't be until the 1980s that the technology was available to save the lives of infants not so perfectly formed.

References:
  1. Curry, James, "Observations on Apparent Death from drowning, hanging, suffocation by noxious vapours, fainting-fits, intoxication, lightning, exposure to cold, & etc., and an account of the means to be employed for recovery. To which are added the treatment proper in cases of poison, with caution and suggestions respecting various circumstances of sudden danger," 2nd edition, 1815, London (the 1st edition was published in 1792)
  2. "The Forty Ninth Annual Report of the Royal Humane Society, For the Recovery of  Persons Apparently Drowned or Dead," 1823, London, 
RT Cave Facebook Page
RT Cave on Twitter
Print Friendly and PDF

Wednesday, April 6, 2016

1792: Curry confirms importance of breathing during artificial during resuscitation

Dr. James Curry obtained all the data of the various societies and came to a variety of conclusions of which he reported to the medical community in 1792 and 1815.  He confirmed that warming the victim was the single most important part of rescue attempts.  (14, pages 36-7)

This verification, partly due to lack of anatomical and pathological knowledge, further stalled the initiation of providing artificial breaths in many instances, and, perhaps, to the detriment of many victims.  As noted above, there was no rush to perform any of these procedures.  There were, in fact, many reported instances where breaths were note given until one or two hours after the person was pulled from danger.

Although, as Curry explained, once better pathological knowledge of the body was obtained, such that circulation of the vital principles (air, oxygen) is vital to sustenance of life, it was learned that "merely restoring Heat to the body, will not renew all the functions necessary to Life."  (14, page 36-37)

It was thus learned that efforts to imitate natural breathing were of superior importance to warming the victim.  (14, page 36-37)

Breathing, therefore, was ultimately viewed by the Humane Society as the "most important part of the process of Resuscitation. As soon as the temperature of the surface has been somewhat raised by means of artificial warmth, about which no time should be lost, early inflation of the lungs is of great consequence. 

Still, if the body be not above the temperature of the surrounding medium in cold weather, its success is very precarious. The temperature of the surface being once raised, artificial warmth and artificial respiration should be simultaneously employed." (12, page 5)

Curry worded it this way: (14, page 37)
In every case of apparent death, the instituting an artificial breathing, by assiduously inflating the lungs with fresh air, is one of the first and most necessary measures to be taken for recovery. (14, page 37)
So, by the advice of Curry, artificial breathing ultimately became the main priority upon removing the victim from eminent danger.  The other methods were either scrapped or moved down the priority list.

References:  See post "1774:  The birth of the Royal Humane Society"

RT Cave Facebook Page
RT Cave on Twitter
Print Friendly and PDF

Wednesday, June 10, 2015

9 B.C.: The first mouth to mouth respirations

This painting from the early 1920s depicts Elisha after
he gave mouth to mouth breaths to revive a Shunamite boy
Mouth-to-mouth breathing was a technique that must have been trialed from time to time by ancient physicians as a last ditch effort to save a life. When it was first attempted will forever remain a mystery, although the first known description of it appeared in the Bible in the Second Book of Kings.

Elisha was born in 9 B.C. When he was a young man he met the prophet Elijah and became his faithful disciple. Elijah at this time was a very old man: he was something like 841 or 821 years old according to the Bible.  

While still a young man he observed his master lifted up to Heaven in a fiery chariot, and he said, "My father, my father, the chariot of Israel...!"  At that moment he stripped off his clothes and declared that he was the successor of Elijah, and his job was to spread the word of the Lord.

The Bible described him as performing many miracles through the guidance of the Hebrew God.  In the Second Book of Kings he is described as successfully resuscitating (or reanimating) the child of a Shunamite woman with mouth to mouth breathing:
And he went up, and lay upon the child, and put his mouth upon his mouth, and his eyes upon his eyes, and his hands upon his hands: and he stretched himself upon the child; and the flesh of the child waxed warm. Then he returned, and walked in the house to and fro; and went up, and stretched himself upon him: and the child sneezed seven times, and the child opened his eyes. (II Kings 4: 34-5)
The depiction here may have been the first recorded use of mouth to mouth breathing. This would entail the physician, in this case the prophet Elisha, placing his mouth over the child's mouth and nose, and exhaling. This would force a positive pressure breath into the child's air passages, thus providing the child with an artificial breath. This procedure may have been performed, albeit rarely, in both the ancient and primitive worlds.  (1)

This scene is estimated to have appeared during the 8th century before the birth of Christ. It is highly likely the procedure was learned by Elisha while he was in training, as most learned individuals of this time were educated in all knowledge of the day, including medical wisdom. So it is highly likely the procedure was tried before in a last ditch effort to save a life.